Use_Del_Reg_Close_N; Port_Punch_Intvl_N; Sip_Add_Rport_N - Panasonic KX-UT248-B Administration Manual

Administration guide
Hide thumbs Also See for KX-UT248-B:
Table of Contents

Advertisement

5.7.2 SIP Settings
Value Range
Default Value

USE_DEL_REG_CLOSE_n

Parameter Name Example
Value Format
Description
Value Range
Default Value

PORT_PUNCH_INTVL_n

Parameter Name Example
Value Format
Description
Value Range
Default Value
Web User Interface Reference

SIP_ADD_RPORT_n

Parameter Name Example
Value Format
Description
256
Administrator Guide
Y (Enable cancelation before registration)
N (Disable cancelation before registration)
N
USE_DEL_REG_CLOSE_1, USE_DEL_REG_CLOSE_2, ...,
USE_DEL_REG_CLOSE_6
Boolean
Specifies whether to enable the cancelation of registration before the
SIP function shuts down when, for example, the configuration has
changed.
Y (Enable registration cancelation before shutting down)
N (Disable registration cancelation before shutting down)
Note
If set to "Y", registration cancelation is enabled.
If set to "N", registration cancelation is disabled even when the
SIP stack is shutting down.
N
PORT_PUNCH_INTVL_1, PORT_PUNCH_INTVL_2, ...,
PORT_PUNCH_INTVL_6
Integer
Specifies the interval, in seconds, between transmissions of the Keep
Alive packet to the unit in order to maintain the NAT binding information.
Note
This setting is available only when "SIP_TRANSPORT_n" is set
to "0" for UDP.
0, 10–300 (0: Disable)
0
Keep Alive Interval (Page 113)
SIP_ADD_RPORT_1, SIP_ADD_RPORT_2, ..., SIP_ADD_RPORT_6
Boolean
Selects whether to add the 'rport' parameter to the top Via header field
value of requests generated. For details, refer to RFC 3581.
Document Version
2012-06