3–50
"C" Group: Intelligent Terminal Functions
Option
Terminal
Code
Symbol
13
THM
27
RMD
*1
Option
Function Name
Code
00
Output frequency
01
Output current
03
Digital output
frequency
04
Output voltage
05
Input power
06
Electronic thermal
overload
07
LAD frequency
Output Function Summary Table
Function Name
Thermal alarm signal
ON
OFF
Run command source
ON
monitor
(–xFU2 and –xFE2
OFF
models only)
Note 1: To ensure safe inverter operation in networked applications, you cannot change an
intelligent terminal assignment to/from [RMD] (option code 27) via the network.
However, you can still read an [RMD] output assignment over the network.
Analog Summary Table - The following table shows all seven functions available for assign-
ment to the three analog output terminals [FM], [AM], [AMI] at a glance. Detailed descrip-
tions, related parameters and settings, and example wiring diagrams are in
Operation" on page
4–54.
Analog Output Function Summary Table
Actual motor speed, represented by PWM
signal
Motor current (% of maximum rated output
current), represented by PWM signal
Output frequency (available only at FM
output)
Rated output voltage to motor
Rated input power
Percentage of electronic overload attained
Internal ramp generator frequency
Description
when the thermal limit for the motor is exceeded
when the thermal limit is not exceeded
when the Run command source is the operator keypad
(A002=02)
when the Run command source is not the operator
keypad (A002=01, 03, 04, or 05)
Description
"Analog Output
Corresponding Signal
Range
0 to max. frequency in Hz
0 to 200%
0 to max. frequency in Hz
0 to 100%
0 to 200%
0 to 100%
0 to max. frequency in Hz

Advertisement