Thermistor Thermal Protection - Hitachi L300P Series Instruction Manual

Three-phase input 200v class; three-phase input 400v class;
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

Thermistor
Motors that are equipped with a thermistor can be protected from overheating. Input terminal
[TH] is dedicated to sense a thermistor resistance. The input can be set up (via B098 and B099)
Thermal
to accept a wide variety of NTC or PTC type thermistors. Use this function to protect the motor
Protection
from overheating.
Valid for
inputs:
Required
settings:
Notes:
• Be sure the thermistor is connected to termi-
Opt.
Symbol
Function Name
Code
TH
Thermistor Thermal
Protection
[TH] only
B098, B099, and C085
nals [TH] and [CM1]. If the resistance is
above or below (depending on whether NTC
or PTC) the threshold the inverter will trip.
When the motor cools down enough, the
thermistor resistance will change enough to
permit you to clear the error. Press the STOP/
Reset key to clear the error.
L300P Inverter
Input
Description
State
Sensor
When a thermistor is connected between
to terminals [TH] and [CM1], the inverter
checks for over-temperature and will
cause a trip (E35) and turn OFF the output
to the motor
Open An open circuit in the thermistor causes a
trip, and the inverter turns OFF the output
Example:
TH
TH
FW
5
P24
PLC
CM1
thermistor
Motor
See I/O specs on page 4–8.
4–27
4
3
2
1

Advertisement

Table of Contents
loading