3–60

Programming Error Codes

Programming Error Codes
Programming Error
Code
001 201
002 202
004 204
005 205
006 206
012 212
015 215
016 216
021 221
025 225
031 231
032 232
035 235
036
037
085 285
086
The L300P inverter operator keypad displays a special code (begins with the
indicate a programming error. Programming errors exist when one parameter conflicts with the
meaningful range permitted by related parameter(s). Note that particular real-time frequency
(speed) input levels can cause a conflict in some situations. After a conflict exists, the error
code will appear on the display, or you can view it later with D090 in Monitor Mode. Also, the
PGM LED on the display will flash ON/OFF when programming. These indications are
automatically cleared when the parameter is corrected to the allowed range.
Parameter out of bounds
Code
Description
A061 / A261
Frequency upper limit
setting; 1st, 2nd motor
A062 / A262
Frequency lower limit
setting; 1st, 2nd motor
A003 / A203
Base frequency setting;
1st, 2nd motor
F001,
Output frequency setting,
A020 / A220
Multi-speed freq. setting;
1st, 2nd motor
A021 to A035 Multi-speed freq. settings
A062 / A262
Frequency lower limit
setting; 1st, 2nd motor
F001,
Output frequency setting,
A020 / A220
Multi-speed freq. setting;
1st, 2nd motor
A021 to A035 Multi-speed freq. settings
A061 / A261
Frequency upper limit
setting; 1st, 2nd motor
F001,
Output frequency setting,
A020 / A220
Multi-speed freq. setting;
1st, 2nd motor
A061 / A261
Frequency upper limit
setting; 1st, 2nd motor
A062 / A262
Frequency lower limit
setting; 1st, 2nd motor
F001,
Output frequency setting,
A020 / A220
Multi-speed freq. setting;
1st, 2nd motor
A021 to A035 Multi-speed freq. settings
A038
Jog frequency setting
F001,
Output frequency setting,
A020 / A220
Multi-speed freq. setting;
1st, 2nd motor
A021 to A035 Multi-speed freq. settings
Boundary defined by...
<, >
Code
>
A004 /
Maximum frequency;
A204
1st, 2nd motor
>
>
>
>
>
A061 / A261
Frequency upper limit setting;
1st, 2nd motor
>
>
<
A062 / A262
Frequency lower limit setting;
1st, 2nd motor
<
<
B082
Start frequency adjustment
<
<
<
<
>f-x,
A063 ± A064
Jump (center) frequency ±
<f+x
A065 ± A066
jump (hysteresis) frequency
A067 ± A068
width setting
>f-x,
(See note after table)
<f+x
character) to
Description