3–42
"B" Group: Fine-Tuning Functions
Free-setting
V/f Pattern
Func.
Name
Code
B100 Free-setting V/f
frequency (1)
B101 Free-setting V/f
voltage (1)
B102 Free-setting V/f
frequency (2)
B103 Free-setting V/f
voltage (2)
B104 Free-setting V/f
frequency (3)
B105 Free-setting V/f
voltage (3)
B106 Free-setting V/f
frequency (4)
B107 Free-setting V/f
voltage (4)
B108 Free-setting V/f
frequency (5)
B109 Free-setting V/f
voltage (5)
B110 Free-setting V/f
frequency (6)
B111 Free-setting V/f
voltage (6)
B112 Free-setting V/f
frequency (7)
B113 Free-setting V/f
voltage (7)
The free-setting V/f inverter mode of operation uses voltage and frequency parameter pairs to
define seven points on a V/f graph. This provides a way to define a multi-segment V/f curve
that best suits your application.
The frequency settings do require that F1 ≤ F2 ≤ F3 ≤ F4 ≤ F5 ≤ F6 ≤ F7; their values must have
this ascending order relationship. To satisfy this criterion during initial parameter editing, set
F7 (B112) and work backwards when setting these values, since the defaults are all 0 Hz.
However, the voltages V1 to V7 may either increase or decrease from one to the next. There-
fore, you may set these parameters in any order.
"B" Function
Description
V/f point 1, frequency
coordinate
V.F point 1, voltage coordi-
nate
V/f point 2, frequency
coordinate
V.F point 2, voltage coordi-
nate
V/f point 3, frequency
coordinate
V.F point 3, voltage coordi-
nate
V/f point 4, frequency
coordinate
V.F point 4, voltage coordi-
nate
V/f point 5, frequency
coordinate
V.F point 5, voltage coordi-
nate
V/f point 6, frequency
coordinate
V.F point 6, voltage coordi-
nate
V/f point 7, frequency
coordinate
V.F point 7, voltage coordi-
nate
Defaults
Run
Mode
Edit
–FE2
–FU2
–FR
Lo Hi
(EU)
(US)
(JP)
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
✘ ✘
0.
0.
0.
✘ ✘
0.0
0.0
0.0
SRW Display
Units
Hz
>b101 FREE-V/F
V1
000.0V
V
>b102 FREE-V/F
F1
0000Hz
Hz
>b103 FREE-V/F
V2
000.0V
V
>b104 FREE-V/F
F2
0000Hz
Hz
>b105 FREE-V/F
V3
000.0V
V
>b106 FREE-V/F
F3
0000Hz
Hz
>b107 FREE-V/F
V4
000.0V
V
>b108 FREE-V/F
F4
0000Hz
Hz
>b109 FREE-V/F
V5
000.0V
V
>b110 FREE-V/F
F5
0000Hz
Hz
>b111 FREE-V/F
V6
000.0V
V
>b112 FREE-V/F
F6
0000Hz
Hz
>b113 FREE-V/F
V7
000.0V
V
>b114 FREE-V/F
F7
0000Hz