Figure 3-27. Cam,Cs Positioning For Reassembly; Figure 3-28. Removing The Sensor Assy.,Pew - Epson DLQ-3000 Service Manual

Terminal printer
Hide thumbs Also See for DLQ-3000:
Table of Contents

Advertisement

It is possible to remove the BOARD ASSY.,CA without removing the CARRIAGE ASSY.
But it is necessay to notice the following.
When the carriage cover is attached for reassembly, set the CAM,CS so that the follow
section faces the CS detector.

Figure 3-27. CAM,CS Positioning for Reassembly

As viewed from front of CARRIAGE.
Note:
3.2.6.12 Removing the SENSOR ASSY., PEW
Step 1 :
Remove the printhead. (Refer to Section 3.2.1.)
Remove the CARRIAGE ASSY. (Refer to Section 3.2.6.10.)
Step 2:
Step 3:
Remove the HOLDER,RIBBON,CARTRIDGE. (Refer to Section 3.2.6.11.)
Remove the wire of the SENSOR ASSY.,PEW from the connector of the BOARD
Step 4:
Step 5:
Remove both screws
MASK, pull off the connectors secured in the carriage, and untie the cords. Then
remove the SENSOR ASSY.,PEW.
The connectors are not easy to insert. For reassembly, insert them firmly using a
screwdriver.
SENSOR ASSY.

Figure 3-28. Removing the SENSOR ASSY.,PEW

Rev. A
Disassembly and Assembly
, BOARD ASSY.,CS
1
AS SY.,PEL'V
RIBBON MASK
3-21

Advertisement

Table of Contents
loading

Table of Contents