It is possible to remove the BOARD ASSY.,CA without removing the CARRIAGE ASSY.
But it is necessay to notice the following.
When the carriage cover is attached for reassembly, set the CAM,CS so that the follow
section faces the CS detector.
Figure 3-27. CAM,CS Positioning for Reassembly
As viewed from front of CARRIAGE.
Note:
3.2.6.12 Removing the SENSOR ASSY., PEW
Step 1 :
Remove the printhead. (Refer to Section 3.2.1.)
Remove the CARRIAGE ASSY. (Refer to Section 3.2.6.10.)
Step 2:
Step 3:
Remove the HOLDER,RIBBON,CARTRIDGE. (Refer to Section 3.2.6.11.)
Remove the wire of the SENSOR ASSY.,PEW from the connector of the BOARD
Step 4:
Step 5:
Remove both screws
MASK, pull off the connectors secured in the carriage, and untie the cords. Then
remove the SENSOR ASSY.,PEW.
The connectors are not easy to insert. For reassembly, insert them firmly using a
screwdriver.
SENSOR ASSY.
Figure 3-28. Removing the SENSOR ASSY.,PEW
Rev. A
Disassembly and Assembly
, BOARD ASSY.,CS
1
AS SY.,PEL'V
RIBBON MASK
3-21