Paper guide (U) Assembly
Separation Rubber
The Separation Rubber can be removed
from the Paper Guide (U) Assembly.
Feed Roller
1. Remove the ground cable by removing
the two screws 5.
2. Remove the Feed Roller by removing
the gear and ADF bearings.
Scan Roller
Remove the Scan Roller by removing the
gear and ADF bearing.
Exit Roller
Remove the Exit Roller while spreading and
holding up the part of the fixing hooks.
Caution: Be careful as not to break the
shaft of the Exit Roller when
removing.
4.3.15
Disassembling the Scanner Unit
(L)
OKIFAX 5700/5900
Feed Roller
Screw 5
Gear
ADF bearings
Gear
ADF bearings
4 - 18
Separation Rubber
Screw 5
Ground cable
Fixing hooks
Exit Roller