Position request setting in Nuendo
In Nuendo, you can access this setting by selecting an op-
tion from the "Position source" pop-up menu in the Sync-
Station Settings pop-up window.
Selecting the RS422 position request sources.

P2out 03 - Position From

P2out 03-Position From
>Serial >Serial+LTC Reader
This is an extension of the position request setting, allow-
ing you to also use the LTC reader in the SyncStation as a
source of position information when the timecode source
is set to RS422 Out. While the serial 9-Pin connection
can communicate position using LTC internally, the addi-
tion of the SyncStation's LTC reader can be useful in cer-
tain situations where there is an issue.
>Serial
This uses the serial 9-Pin RS422 connection exclusively
for position requests.
>Serial+LTC Reader
This allows the LTC reader to be used as another source
of position information for the SyncStation when RS422 is
set as the timecode source.
Position from setting in Nuendo
In Nuendo, this setting can be changed from the Sync-
Station Settings pop-up window with the "Position from
RS422-Out+LTC" check box. When deactivated, the
SyncStation will use the serial port only.

P2 In menu

The RS422 input is used to remotely control the Sync-
Station as a virtual machine from an external master con-
troller. When enabled, the SyncStation will appear as
another 9-Pin device to the external controller.

P2in 01 - Device ID

P2in 01-Device ID
>RS422-Out >Nuendos >Nuendot >3324 >A500
The external controller will identify the SyncStation by the
ID set in this menu.
>RS422-Out
When set to RS422-Out, the SyncStation will identify it-
self to the controller as the same type of device that is
connected to the SyncStation's 9-Pin out connector.
>Nuendos
Identifies the SyncStation as "Nuendo SyncStation".
>Nuendot
Identifies the SyncStation as "Nuendo Timebase".
>3324
Identifies the SyncStation as a Sony 3324 DASH Digital
Multitrack machine.
>A500
Identifies the SyncStation as a Sony A500 VTR, a very
common 9-Pin profile.
Setting the P2 In device ID in Nuendo
The P2 In device ID can be set in Nuendo from the Sync-
Station Settings pop-up window by selecting an entry
from the Device ID pop-up menu.
Setting the P2 In device ID to A500.