Maintenance Error Codes

Error
Code
0001 TIMEOUT COLD
START:
System programming OK.
0002 POWER UP WARM
START:
System programming OK.
0003 SOFTWARE COLD
START:
System programming OK.
0004 SOFTWARE WARM
START:
System programming OK.
0005 Reset - DIAGNOSTIC
SWITCH:
0006 INCOMPLETE COLD
START:
System cold-started while
restart in progress.
0007 SANITY TIMEOUT
RESET:
Faulty software, module,
carrier, or processor sanity
timer.
0008 MAX RESET COUNT
EXCEEDED:
System cold-started because
of too many warm starts.
0009 FRIGID START:
System restarted and
initialized to defaults;
also logged after System
Erase.
Description
Technical Addendum
Action
No action required;
however, if problem
persists, troubleshoot the
processor.
No action required;
however, if problem
persists, troubleshoot the
processor.
If problem persists,
troubleshoot the processor.
If problem persists,
troubleshoot the processor.
If problem persists,
troubleshoot the processor.
Check module and/or
processor.
If problem persists,
troubleshoot the processor.
If processor was removed
while in use, system may
perform frigid start because
of loss of system
programming. Restore
system as described in
System Programming and
Maintenance (SPM) .