Lucent Technologies MERLIN LEGEND Release 6.1 Pocket Reference page 14

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Pocket Reference 555-661-116
Release 5.0 Enhancements (June, 1997)
System Requirements for CTI link
Refer to Chapter 2 of the Network Manager's Guide for detailed
installation instructions.
The following equipment and software are required:
An Intel i386, Intel i486, or Pentium class computer with at least
16 megabytes of RAM. Additional memory may be needed if
additional applications will be running on the server machine.
NetWare Version 4.10 or Version 3.12
5 megabytes of disk space available on the SYS (system)
volume
Telephony Services for NetWare software, Releases 2.21 or
later, installed
An Eicon/G. Diehl SCOM card for the CTI link
A free 8- or 16-bit ISA slot for the Eicon/G. Diehl SCOM card
System software Release 5.0 or later installed on the MERLIN
LEGEND Communications system
The MERLIN LEGEND configured in Hybrid/PBX mode
An MLX port board (using firmware Version 28 or later, except
Version 29) installed in the MERLIN LEGEND
NOTE:
The 008 MLX and 408 MLX modules must have firmware
vintage other than 29. If the module has firmware 29,
programming a CTI link on the module is prevented. An earlier
or later vintage firmware is supported.
If the MERLIN LEGEND switch has only one MLX port board,
you also need System Programming and Maintenance (SPM)
software, Version 5.01, to program the CTI link
One port on the MLX board is used for the CTI link. This port
cannot be a potential operator port (2, 3, 4, 6, 7, and 8 must be
available) or a console programming port
For a NetWare 3.12 installation, ensure that either
NWSNUT.NLM, Version 4.11 or later, and TUI.NLM, Version
1.04 or later, is obtained from Novell and installed in the
SYS:\SYSTEM directory
NOTE:
To obtain these NLMs from Novell, access either the Novell
web site (http:\\www.novell.com) or the Novell FTP site
(ftp.novell.com). First, download IPXRT4.EXE and follow the
directions in the associated readme file. Then, download
NWSNUT.NLM and TUI.NLM.
Basic Call Control. A CTI link application on a user's computer
can assume basic call control of the user's analog multiline or
MLX telephone's SA buttons. Basic call control includes:
Answering calls arriving on an SA button
Making calls from an SA button
Hanging up calls
Hold and retrieving a call on hold at the user's extension
Conference calls from a DLC or QCC operator
Issue 1
August 1998
Page 8

Advertisement