Lucent Technologies MERLIN LEGEND Release 6.1 Pocket Reference page 128

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Pocket Reference 555-661-116
Technical Addendum
Technical Addendum
Maintenance Error Codes (continued)
Error
Code
6C0B
HARDWARE
INOPERATIVE:
Hardware not operating
properly. If this is the only
100D module or 800 NI-BRI
module, or if this is the
designated clock module,
its TDM bus clock generator
was not activated.
6C0C
BRI LOSS OF SYNC:
Service on link has been
lost.
6C0D
BRI SLIPS > 88:
Slip count > 88. Service on
link is still operative.
6C0E
BRI NET REQUESTED
CCRCs:
Outgoing signal to the
network does not have valid
framing information. Service
on link is still operative.
6C0F
BRI NET
DEACTIVATE:
Layer 1 of the link is down.
Service on link has been
lost.
6C10
BRI NET INV 2B+D
LB ACT:
Service on link has been
lost.
Description
Action
A Busy-Out/Restore or
Reset/Restore may clear
problem. If problem
persists, contact NSAC
Tier III.
Usually none; check BRI
facility. If problem
persists, contact NSAC
Tier III.
Usually none; check BRI
facility. If problem
persists, contact NSAC
Tier III.
Usually none; link should
return to normal once test
is completed. If problem
persists, contact NSAC
Tier III.
Usually none; link should
return to normal once test
is completed. If problem
persists, contact NSAC
Tier III.
Usually none; link should
return to normal once test
is completed. If problem
persists, contact NSAC
Tier III.
Issue 1
August 1998
Page 122

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend

Table of Contents