MERLIN LEGEND Communications System Release 6.1
Pocket Reference 555-661-116
Technical Addendum
Maintenance Error Codes (continued)
Error
Code
2C02
Bearer Capability
Incompatibility:
A 64 kbps clear-channel
data call was routed to a
facility that does not have
sufficient bandwidth to
handle the call.
3001
ALARM TABLE FULL:
Error logs are full; turns on
processor LED.
4401
USER REQUESTED
SYS ERASE:
Logged after System Erase.
If System Erase is
successful, this error is
removed immediately.
4402
USER REQST
UPGRD/INSTALL:
4C01
POOL EMPTY:
The system needed to use
a trunk in a pool but no
trunks were physically
present in the pool, i.e., all
of the boards were removed
from the system.
Description
Technical Addendum
Action
Verify that the ARS or UDP
routing tables route a data call
to a DS1 facility. Check the
DS1 Type administration item
for the specified facility. If the
programmed value is T1 , the
caller must initiate a 56 kbps
call. Check the DS1
Suppression administration
item for the specified facility. If
the programmed value is
AMI-ZCS , the caller must
initiate a 56 kbps call.
Correct indicated errors, and
then remove entries from the
transient system error log. If
problem persists, cold-start
the system.
SysProgram System
Restart
If error remains in transient
log, repeat System Erase. If
problem persists, check
processor.
None.
Replace boards.
Issue 1
August 1998
Page 119
Need help?