OIL FILTRATION INSTRUCTIONS (FOR UNITS WITH INSTALLED OPTION)
CLEANING & MAINTENANCE
O IL D ISCA RD H OSE OP T I O N :
The oil discard hose option (HO-27686) is available
as an option to assist both the boil-out and
filtration operation.
With the discard hose attached to the nozzle
connection, place the Kettle/Nozzle selector
in the "NOZZLE" position.
ASF-75G, 120V WITH FILTRATION
nozzle
connection
nozzle
kettle
selector
The drain can be placed in the "OPEN" or
"CLOSED" position as required.
Disconnect hose following use and return the
selector to the "KETTLE FILL" position.
Nozzle will contain a small amount of oil after use.
Dispose of properly.
D A N G E R
TO AVOID SERIOUS PERSONAL
INJURY DO NOT STAND ON THE
FRYER OR FRYER COVER. THE
FRYER COVER IS DESIGNED TO
HOLD A MAXIMUM OF 10-POUNDS
(4,5 KG) OF WEIGHT.
Gas F ryer Operati on & Care Manual • 21
O P E R A T I O N