D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
An electrical wiring diagram is located in the front
access door of the fryer. The fryer must be installed by a
qualified electrician. This appliance must be branch circuit
protected with proper ampacities, in accordance with
the wiring diagram located in the fryer. The fryer must
be properly grounded in accordance with the National
Electrical Code and applicable local codes. A means to
disconnect the unit must be incorporated into the fixed
wiring in accordance with wiring codes.
Wire size for the main incoming power to the unit must
match the minimum size listed in the specifications
applicable to the specific fryer. For supply connections,
locate the wire size posted on the label located on the
electrical control box cover, behind the service panel or
elsewhere listed in this manual.
Before operating the fryer, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
ELECTRICAL • ASF-60G
/
voltage
phase
cycle
hz
120 (
)
1
60
agcy
230
1
50
with basic control
w
&
amps
k
cord
2.2
0.27
5-15p
n e m a
15a-125v
1.0
0.23
7 / 7
c e e
220-230v
Gas F ryer Operati on & Care Manual • 11
E L E C T R I C A L R E Q U I R E M E N T S
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in close
vicinity, an equalization-bonding stud is provided. An
equalization bonding lead must be connected to this
stud and the other appliances / metal parts to provide
sufficient protection against potential difference. The
terminal is marked with the following symbol.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
ELECTRICAL • ASF-75G
plug
voltage
120 (
)
agcy
plug
230 (
) 1
agcy
plug
I N S T A L L A T I O N
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
with basic control
/
w
phase
cycle
hz
amps
k
1
60
7.2
0.86
50
4.0
0.92
5-15p
nema
15a-125v
plug
7/7
cee
220-230v
plug