Switch Setup To Run Crossporttest; System Memory Test - IBM 2109 - SAN Fibre Channel Switch Model S16 Service Manual

San fibre channel switch
Table of Contents

Advertisement

Figure 37. Switch setup to run crossPortTest
Note: All ports on the switch must be connected or else the switch shows an error
If an error is encountered during the test, the error displays on either the front panel
display or during the Telnet session.
Related error messages: DIAG-INIT, DIAG-PORTDIED, DIAG-XMIT,
DIAG-TIMEOUT, DIAG-ERRSTAT, DIAG-STATS, DIAG-PORTWRONG, DIAG-DATA,
DIAG-PORTABSENT.
Display test
Pressing Enter while the Display test command is selected displays a series of test
characters. Use this test to determine that the display is functioning properly.
Display test long
Pressing Enter while the Display test long command is selected causes a series of
test characters to display. Use this test to determine that the display is functioning
properly.
Memory test
Pressing Enter while the ramTest command is selected activates the display shown
in Figure 38.
Figure 38. System memory test
If the memory test is OK, the front panel activates the display shown in Figure 39
98
IBM SAN Fibre Channel Switch: 2109 Model S16 Installation and Service Guide
condition. When running the crossPortTest command, you must set the
operating mode value to 0 or 1. Modes 2 and 3 do not send out the
extended link parameters (ELP) used to discover switches. If the ELP is not
sent, the switch does not know that the port is connected to another port on
the same switch and the test fails.
System Memory Test at
0x1021d460 len 13091456
on page 99.
Fiber Channel Switch 2109 S16