Cmemretention Test Example; Cmitest Example - IBM 2109 - SAN Fibre Channel Switch Model S16 Service Manual

San fibre channel switch
Table of Contents

Advertisement

|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| |
| |
| |
|
|
|
|
|
|
| |
| |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
96
IBM SAN Fibre Channel Switch: 2109 Model S16 Installation and Service Guide
Table 30. centralMemoryTest example (continued)
Example
sw7:admin> centralMemoryTest
Running Central Memory Test ... passed.
Related error messages: DIAG-CMBISTRO, DIAG-CMBISRF, DIAG-LCMTO,
DIAG-LCMRS, DIAG-LCMEM, DIAG-LCMEMTX, DIAG-CMNOBUF,
DIAG-CMERRTYPE, DIAG-CMERRPTN, DIAG-PORTABSENT, DIAG-BADINIT,
DIAG-TIMEOUT.
cmemRetention test
Table 31 shows the cmemRetentionTest command, which is used to verify that
data written into the SRAMs that make up the central memory are retained and that
data bits do not drop when read after some amount of delay since the write
operation.
Attention:
This command cannot be executed on an operational switch. Before
using the cmemRetention test command, disable the switch using the
switchDisable command.
cmemRetention test example: The cmemRetention Test command performs a
data retention test of the central memory SRAMs.
Table 31. cmemRetention test example
Synopsis
cmemRetentionTest [passCount]
Availability
Administrator
Description
Use this command to verify for data retention in the central memory
SRAMs in the ASIC.
Below are possible error messages if failures are detected:
DIAG-LCMRS
DIAG-LCMTO
DIAG-LCMEM
Operands
This command has the following operand:
passCount
Example
sw7:admin> cmemRetentionTest
Running CMEM Retention Test ... passed.
Related error messages: DIAG-LCMEM, DIAG-LCMRS, DIAG-LCMTO.
cmiTest
Table 32 on page 97 shows the cmiTest command, which verifies that control
messages can be correctly sent from any ASIC to any ASIC. It also tests that the
checksum check is OK.
Attention:
This command cannot be executed on an operational switch. Before
issuing the cmiTest command, disable the switch using the switchDisable
command.
cmiTest example: The cmiTest command performs a ASIC to ASIC connection
test of the CMI bus
Specify the number of times to execute this test. The
default value is 1. This operand is optional.

Advertisement

Table of Contents
loading

This manual is also suitable for:

2109 s16

Table of Contents