Enabling Bi-Directional Chap During Discovery Session And Bi-Directional Chap During Normal Session; Chap Bi-Directional Settings - HP StorageWorks 6400/8400 - Enterprise Virtual Array User Manual

Hp storageworks mpx200 multifunction router user guide (5697-0202, february 2010)
Hide thumbs Also See for StorageWorks 6400/8400 - Enterprise Virtual Array:
Table of Contents

Advertisement

Enabling bi-directional CHAP during discovery session and bi-directional CHAP
during normal session
Table 13
lists the settings you use to enable bi-directional CHAP during a discovery session and
bi-directional CHAP during a normal session.
Table 13 CHAP bi-directional settings
MPX200 secret settings
Source
iSCSI Port
Discovered iSCSI
initiator
iSCSI Presented
Target
NOTE:
These are examples of secret settings. Configure CHAP using settings that apply to your network
environment.
1.
Enable CHAP for the MPX200 discovered iSCSI initiator entry (CHAP can be enabled via CLI
only):
a.
If the iSCSI initiator is not listed when you execute the set chap command, do one of the
following:
• From HP Command View EVA, select Hosts and then select the Add Host tab. Enter the
IQN name string.
• From the CLI, enter the initiator add command and add the iSCSI initiator that will
perform the discovery.
b.
If the iSCSI initiator is listed under the set chap command, enable CHAP secret (for
example: CHAPsecret01).
a.
b.
2.
Enable CHAP for the MPX200 iSCSI port:
a.
To enable CHAP for the MPX200 iSCSI port using HP Command View:
• Select the appropriate iSCSI Controller, then select the IP Ports tab, and then select the
appropriate IP Port.
• Under Security, select Enabled in CHAP Status, and then enter the CHAP Secret (for ex-
ample: hpstorageworks).
• Select the Save Changes tab to save the changes.
b.
Enable CHAP for the MPX200 iSCSI port using the MPX200 CLI:
• Enter the set chap command.
• Select the appropriate Portal iqn name index that the initiator will log in to.
• Select 0 to enable CHAP.
• Enter a CHAP secret (for example: hpstorageworks).
110
MPX200 iSCSI configuration rules and guidelines
Setting (example)
hpstorageworks
CHAPsecret01
hpstorageworks
Select the index of the iSCSI initiator.
To Enable CHAP, select 0, then enter the CHAP secret.
Microsoft initiator secret settings
Action
General Tab Secret
Add Target Portal
Log on to Target
Setting (example)
hpstorageworks
CHAPsecret0
CHAPsecret01

Advertisement

Table of Contents
loading

Table of Contents