HP StorageWorks 6400/8400 - Enterprise Virtual Array User Manual page 332

Hp storageworks mpx200 multifunction router user guide (5697-0202, february 2010)
Hide thumbs Also See for StorageWorks 6400/8400 - Enterprise Virtual Array:
Table of Contents

Advertisement

QLBA_CreateTargetDeviceO-
41058
bject: Too many devices
QLBA_CreateTargetNodeOb-
41060
ject: Too many devices
QLBA_CreateLunObject:
41067
LunObject memory unavail-
able
QLBA_CreateInitiatorOb-
41077
ject: Too many initiators
QLBA_DisplayTargetOpera-
41096
tionStatus: PCI Error,
Status 0x%.2x
QLBA_DisplayInitiatorOper-
41106
ationStatus: DMA Error,
Status 0x%.2x
QLBA_DisplayInitiatorOper-
41107
ationStatus: Transport
Error, Status 0x%.2x
QLBA_DisplayInitiatorOper-
41111
ationStatus: Data Over-
run, Status 0x%.2x
QLIS_LoginPduContinue:
41234
Operation failed. Initiat-
or 0x%x, TPB status 0x%x
QLKV_ValidateLoginTrans-
41238
itCsgNsgVersion failed
(status 0x%x)
QLIS_LoginPduContinue:
41257
Invalid initiator name.
Initiator:
QLIS_LoginPduContinue:
41265
Target not configured for
Portal
QLIS_LoginPduContinue:
41267
Target not found. Target
name:
QLIS_LoginPduContinue:
41268
Missing target name
QLIS_LoginPduContinue:
TSIH is 0 but Initiator-
41270
Name key/value not
provided
332
Log messageslog messages
Unable to create an object for the target
App
Error
device; exceeded the maximum number of
target devices.
Unable to create an object for the target node;
App
Error
exceeded the maximum number of target
devices.
App
Error
Memory unavailable for LUN object.
Unable to create an object for initiator object;
App
Error
exceeded the maximum number of initiators.
Process control block status indicates that a
App
Error
peripheral component interface/interconnect
(PCI) error occurred during a target operation.
Process control block status indicates that a
App
Error
direct memory access (DMA) error occurred
during an initiator operation.
Process control block status indicates that a
App
Error
transport error (protocol) occurred during an
initiator operation.
Process control block status indicates that a
App
Error
data overrun error occurred during an initiator
operation.
iSCSI login failed between receipt of protocol
App
Error
data unit (PDU) and request for the data seg-
ment.
iSCSI login failed due to unsupported version
App
Error
number in received login PDU.
iSCSI login PDU contains invalid initiator
App
Error
name. The format and character set used to
form the initiator name is invalid.
iSCSI target login was attempted to a portal
App
Error
(iSCSI1 or iSCSI2) on which the target is not
presented.
iSCSI login PDU received for a target with a
App
Error
target name unknown to the router.
iSCSI login PDU received without a target
App
Error
name for a normal session.
iSCSI login PDU received without an initiator
App
Error
name key/value.

Advertisement

Table of Contents
loading

Table of Contents