#%d: QLIoctlDisable: Re-
106593
initialize adapter failed
#%d: QLIsrEventHandler:
106803
Link down (%x)
#%d: QLIsrEventHandler:
Unexpected async event
106813
(%x), MB1=%x, MB2=%x,
MB3=%x, MB4=%x, MB5=%x,
MB6=%x, MB7=%x
#%d: QLProcessRespon-
106847
seQueue: Invalid
EntryStatus %x, type %x
#%d: QLTimer: Heartbeat
106851
failed
#%d: QLTimer: Link error
106853
count (0x%x) exceeded,
link down
#%d: QLReserveLoopId: out
106912
of loop Ids
#%d: QLMarkDeviceOffline:
Device Id: %x marked off-
106928
line, cLinkDownTimeout =
%x, cPortDownRetryCount=
%x
#%d: QLSnsGetAllNext:
106948
Name server login FAILED
%x
#%d: QLUpdateDeviceData:
107029
out of slots in host
database
#%d: QLUpdateDeviceData:
107030
out of slots in target
database
#%d: QLUpdateDeviceData-
107041
base 0x%x: GET_ID failed
%x
#%d: QLUpdateDeviceDatabase
107056
0x%x: out of slots in host
database
#%d: QLUpdatePort 0x%x:
107078
out of slots in host
database
342
Log messageslog messages
FC processor failed to re-initialize in response
FC
Error
to an IOCTL disable request.
FC
Error
FC processor reported a link down condition.
FC processor reported an unexpected asyn-
chronous event. The mailbox registers provide
FC
Error
status, event code, and data related to the
event.
FC controller reported an invalid Entry Status
FC
Error
%x, type %x.
FC
Error
FC controller failed to provide a heartbeat.
Driver has determined that the FC link is unre-
liable and unusable due to the number of er-
FC
Error
rors encountered. The link has been taken
down.
FC processor was unable to obtain the number
of loop IDs required. This failure occurs only
FC
Error
when the FC processor is running multi-ID
firmware.
Driver was unable to re-establish connection
FC
Error
to the target within the timeout and retry
counts, and is therefore marking it offline.
FC processor is unable to log into the FC fabric
FC
Error
name server.
FC
Error
Driver's host (initiator) database is full.
FC
Error
Driver's target database is full.
Driver's host (initiator) database is full. Maxim-
FC
Error
um hosts is 64.
FC
Error
Drivers host (initiator) database is full.
Driver was unable to re-establish connection
FC
Error
to the target within the timeout and retry
counts, and is therefore marking it offline.

Advertisement