Enclosure Power Supply Status Changed To Non Redundant - HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

Table 6-79
HP_DeviceIndication: Logical Drive is in a degraded state
Property name
SystemVirtualUUID
Enclosure Power Supply status changed to Non
6-2-10
Redundant
Table 6-80
HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
ProviderVersion
Property implementation
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Property implementation
CIM_Indication
GUID string generated at the time of indication
3 (Warning)
Time of indication
CIM_AlertIndication
A Storage Enclosure Power Subsystem status has
changed to non-redundant.
WBEM Path of HP_StorageEnclosureProcessor
2 (CIMObjectPath)
5 (Device Alert)
301
Time of the event or time of the indication if event time
unknown
HP SAS
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Power Supply status Non-Redundant
17 (Primary Storage Power)
89 (Power Supply Failure)
Redundant Power Supply Status Changed to Non-
Redundant
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SMX_SAS HBA Provider 208

Advertisement