HP ProLiant BL280c - G6 Server Datasheet page 201

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

Table 6-76
HP_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
ProviderVersion
NetworkAddresses
OSType
OSVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
Property implementation
Time of indication
CIM_AlertIndication
A physical drive status has changed to Predictive
Failure.
WBEM Path of disk drive
2 (CIMObjectPath)
5 (Device Alert)
204
Time of the event or time of the indication if event time
unknown
HP SAS
Replace drive immediately to avoid loss of data.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Physical drive predictive failure
6 (Primary Storage)
86 (Disk Failure)
Physical Drive Predictive Failure
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
SMX_SAS HBA Provider 201

Advertisement

Table of Contents
loading