Table 10-4
Class: SMX_PowerRedundancySet
Property name
InstanceID
MaxNumberSupported
MinNumberNeeded
TypeOfSet
LoadBalanceAlgorithm
RedundancyStatus

SMX_MemberOfPowerRedundancy

10-3-4
SMX_MemberOfPowerRedundancy is used to represent an association between HP_PowerSupply and
HP_PowerRedundancySet.
Table 10-5
Class: SMX_MemberOfPowerRedundancy
Property name
Collection
Included
Member
Property implementation
CIM_SystemSpecificCollection
Unique identifier for this power redundancy instance
CIM_RedundancySet
The maximum number of power supplies supported for
this redundancy set
The minimum number of power supplies needed to
function
3 (Load Balanced)
0 (Unknown)
0 (Unknown) – if the redundancy status is unknown
2 (Fully Redundant) – if the all power supplies in the set
are operating properly and enough to achieve
redundancy
3 (Degraded Redundancy) – if there are at least
enough power supplies for the redundancy set to
provide power, but power supplies have failed
4 (Redundancy Lost) – if there are not enough power
supplies required to achieve redundancy, but there are
enough for the redundancy set to provide power
5 (Overall Failure) – if there are not enough power
supplies operating properly for the redundancy set to
provide power.
Property implementation
References HP_PowerRedundancySet
Writeable boolean property indicating if the power
supply instance referenced by Member will contribute
status to the HP_PowerCollection.
TRUE: Include member status in collection status
FALSE: Do not include member status in collection
status
References HP_PowerSupply