Hp_Deviceindication: Controller Status Changed To Error - HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

HP_DeviceIndication: Controller Status Changed to
4-4-8
OK
Table 4-102
HP_DeviceIndication: Controller Status Changed to OK
Property name
VariableValues[]
DeviceModel
HP_DeviceIndication: Controller Status Changed to
4-4-9
ERROR
Table 4-103

HP_DeviceIndication: Controller Status Changed to ERROR

Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
Property implementation
FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
Array Controller Model string
Property implementation
CIM_Indication
GUID string generated at the time of indication
5 (Major)
Time of indication
CIM_AlertIndication
A Smart Array controller status has changed to Error.
WBEM Path to SMX_SAArrayController class.
2 (CIMObjectPath)
5 (Device Alert)
2
Time of the event or time of the indication if event time
unknown
HP Smart Array
Check controller status and run diagnostics.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Controller status Error
6 (Primary Storage)
Smart Array 110

Advertisement

Table of Contents
loading

Table of Contents