Table 10-3
Class: SMX_PowerCollection
Property name
GroupOperationalStatus[0]
GroupStatusDescriptions[0]

SMX_PowerRedundancySet

10-3-3
SMX_PowerRedundancySet is used to model power supply redundancy sets on Servers.
Table 10-4
Class: SMX_PowerRedundancySet
Property name
Caption
Description
ElementName
Property implementation
HP_GroupSystemSpecificCollection
Represents the most severe power redundancy status
and non-fault tolerant power supply operational status:
0 (Unknown) —If power collection status is unknown
2 (OK) —If power supplies are operating properly
3 (Degraded) —If no
SMX_PowerSupply.OperationalStatus[0] for all non-
fault tolerant power supplies report 6 (Error) and
SMX_PowerRedundancySet.RedundancyStatus for any
power redundancy sets report 3 (Degraded
Redundancy) or 4 (Redundancy Lost) and no power
redundancy sets report 5 (Overall Failure).
6 (Error) —If SMX_PowerSupply.OperationalStatus[0]
for any non-fault tolerant power supplies report 6
(Error) or if
SMX_PowerRedundancySet.RedundancyStatus for any
power redundancy sets report 5 (Overall Failure).
Note: If the system starts up with a redundancy status
set to 4 (Redundancy Lost) and no power supplies have
been removed or failed, the GroupOperationalStatus
will be set to 2 (OK) because this is a valid
configuration.
Unknown status for power supplies, if
GroupOperationalStatus[0] is 0 (Unknown)
Power supplies are operating properly, if
GroupOperationalStatus[0] is 2 (OK)
Power supplies are degraded, if
GroupOperationalStatus[0] is 3 (Degraded)
Power supplies have failed, if
GroupOperationalStatus[0] is 6 (Error)
Property implementation
CIM_ManagedElement
Power Redundancy Set n, where n represents the
number of the redundancy set instance
Power Redundancy Set n is collection of fault tolerant
power supplies that provide redundant power.
n represents the number of the redundancy set instance
Power Redundancy Set n, where n represents the
number of the redundancy set instance