HP ProLiant BL280c - G6 Server Datasheet page 106

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

SMX_SAStorageVolumeIndication: Logical Drive
4-4-7
Status Changed to Degraded
Table 4-101
SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded
Property name
EventTime
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
Summary
EventCategory
ProbableCause
ProbableCauseDescription
NetworkAddresses
OSType
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
ImpactedDomain
Property implementation
Time of the event or time of the indication if event time
unknown
HP Smart Array
Check status of physical drives. Degraded status may
be caused by failed or missing physical drives, or a
data recovery operation on one or more physical
drives.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Logical drive status in degraded state
6 (Primary Storage)
86 (Disk Failure)
Logical State Changed to Degraded
Contains a list of all the IP addresses of the computer
system generating the indication
SMX_OperatingSystem.OSType
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
2.2.0.0
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note: When ImpactedDomain is 3 (Enclosure) the
properties indicated with (*) are populated.