Smx_Fan - HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

SMX_Fan

9-3-1
SMX_Fan is used to model fans on Servers. Please note: fan numbers for existing instances do not
change when other fans are added and removed.
Table 9-2
Class: SMX_Fan
Property name
Caption
Description
ElementName
OperationalStatus[0]
StatusDescriptions[0]
HealthState
Name
CreationClassName
DeviceID
SystemCreationClassName
Property implementation
CIM_ManagedElement
Short description of this fan from the name displayed
by the MP or iLO and the location.
For example: Fan 1 at CabinetFan=01
Description of this fan, including ElementName,
FanType and StatusDescription[0].
For example: elementname provides cooling for
fantype. statusdescription.
where elementname represents the value of
ElementName ,
fantype represents the corresponding string value of the
FanType enumeration and
statusdescription represents the value of
StatusDescriptions[0]
Short description of this fan from the name displayed
by the MP or iLO and the location.
For example: Fan 1 at CabinetFan=01
CIM_ManagedSystemElement
2 (OK)—if fan is operating properly
3 (Degraded)—if fan is degraded
6 (Error)—if fan has failed
Description of the status of the fan correcponding to the
OperationStatus
Fan is operating properly—if OperationalStatus[0] is 2
(OK)
Fan is degraded – if OperationalStatus[0] is 3
(Degraded
Fan has failed—if OperationalStatus is 6 (Error)
5 (OK)—if fan is operating properly
10 (Degraded) if fan is degraded
20 (Major Failure)—if fan has failed
Unique name fo this fan
Fan n, where n represents the number of the fan
instance.
CIM_LogicalDevice
SMX_Fan
Unique identifier for this fan instance
SMX_ComputerSystem.CreationClassName
System Fan 269