Product Ver:
Diagnostic Status:
Internal Data
Device Failure
Power Cord

SHOW ENCLOSURE STATUS

Command:
SHOW ENCLOSURE STATUS
Description:
Displays the basic health and status of the enclosure subsystem
Access level/Bay level:
All
Restrictions:
None
Example
OA-0018FE27577F> SHOW ENCLOSURE STATUS
Enclosure:
Status: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data
Onboard Administrator:
Status: OK
Power Subsystem:
Status: OK
Power Mode: Not Redundant
Power Capacity: 3600 Watts DC
Power Available: 2685 Watts DC
Present Power:
Cooling Subsystem:
Status: OK
Fans Good/Wanted/Needed: 6/6/5
Fan 1:
9497 RPM (53%)
Fan 2:
7342 RPM (41%)
Fan 3:
9493 RPM (53%)
Fan 4:
9495 RPM (53%)
Fan 5:
7343 RPM (41%)
Fan 6:
9508 RPM (53%)

SHOW ENCLOSURE TEMP

Command:
SHOW ENCLOSURE TEMP
Description:
Displays:
Locale
o
Status (OK, warm, degraded, or failed)
o
Temperature in degrees Fahrenheit
o
OK
OK
OK
OK
463 Watts AC