Logical Drive Status Error - HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

Table 6-77
HP_DeviceIndication: Logical Drive status OK
Property name
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID

Logical Drive status ERROR

6-2-8
Table 6-78
HP_DeviceIndication: Logical Drive status ERROR
Property name
IndicationIdentifier
PreceivedSeverity
IndicationTime
Description
AlertingMangedElement
AlertingElementFormat
AlertType
Property implementation
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Property implementation
CIM_Indication
GUID string generated at the time of indication
5 (Major)
Time of indication
CIM_AlertIndication
A logical drive status has changed to Error.
WBEM Path of Storage Volume
2 (CIMObjectPath)
5 (Device Alert)