Smx_Fanredundancyset - HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

Table 9-3
Class: SMX_FanCollection
Property name
GroupOperationalStatus[0]
GroupStatusDescriptions[0]

SMX_FanRedundancySet

9-3-3
SMX_FanRedundancySet is used to model fan redundancy sets on Servers.
Table 9-4
Class: SMX_FanRedundancySet
Property name
Caption
Description
ElementName
Property implementation
Represents the most severe cooling redundancy status
and non-fault tolerant fan operational status:
0 (Unknown)—if fan collection status is unknown
2 (OK)—if fans are operating properly
3 (Degraded)—if no SMX_Fan OperationalStatus[0] for
all non-fault tolerant fans report 6 (Error) and
SMX_FanRedundancy.RedundancyStatus for any
cooling redundancy sets report 3 (Degraded
Redundancy) or 4 (Redundancy Lost) and no cooling
redundancy sets report 5 (Overall Failure)..
6 (Error)—if SMX_Fan.OperationalStatus[0] for any
non-fault tolerant fans report 6 (Error) or
SMX_FanredundancySet.RedundancyStatus for any
cooling redundancy sets report 5 (Overall Failure). If
the system starts up with a redundancy status set to 4
(Redundancy Lost) and no fans have been removed or
failed, the GroupOperationalStatus is set to 2 (OK)
because this is a valid configuration
Unknown status for fans, if GroupOperationalStatus[0]
is 0 (Unknown);
Fans are operating properly, if
GroupOperationalStatus[0] is 2 (OK);
Fault tolerant fans are degraded, if
GroupOperationalStatus[0] is 3 (Degraded);
Fans have failed, if GroupOperationalStatus[0] is 6
(Error)
Property implementation
CIM_ManagedElement
Short description of this redundancy set, for example
Cooling Redundancy Set n
Where n represents the number of the redundancy set
instance
Cooling Redundancy Set n is collection of fault tolerant
fans that provide redundant cooling.
n represents the number of the redundancy set instance
User printable name for this colling redunance set. For
example, Cooling Redundancy Set n, where n
represents the number of the redundancy set instance
CIM_SystemSpecificCollection
System Fan 271

Advertisement

Table of Contents
loading

Table of Contents