SMX_HostedSensorCollection

12-2-5
SMX_HostedSensorCollection implements HP_HostedSensorCollection and is used to represent an
association between SMX_SensorCollection and the computer system that contains the collection.
Table 11-5
Class: SMX_HostedSensorCollection
Property name
Antecedent
Dependent

SMX_SystemSensor

12-2-6
SMX_SystemSensor implements HP_SystemSensor and is used to represent an association between
SMX_NumericSensor and the computer system that contains the sensor.
Table 11-6
Class: SMX_SystemSensor
Property name
GroupComponent
PartComponent

Supported indications

12-3
The following indications are implemented for ProLiant server platforms where available.
Table 11-7
HP_AlertIndication_: Temperature Sensor Threshold Exceeded
Property name
IndicationIdentifier
PerceivedSeverity
IndicationTime
Description
AlertingManagedElement
AlertingElementFormat
AlertType
EventID
Property implementation
References SMX_ComputerSystem
References SMX_SensorCollection
Property implementation
References SMX_ComputerSystem
References SMX_NumericSensor
Property implementation
CIM_Indication
GUID string generated at the time of indication
5 (Major)
Time of indication
CIM_AlertIndication
A temperature sensor has detected that the temperature
has exceeded the normal operating range.
(SensorCaption)" where SensorCaption is the
SMX_NumericSensor.Caption for the sensor that has
failed
WBEM path of the SMX_NumericSensor instance
representing the temperature sensor detecting the
exceeded threshold
2 (CIMObjectPath)
5 (Device Alert)
1
System Temperature Sensor 322