Rcs-Rcsdisabled - HP StorageWorks 16-EL - SAN Switch Reference Manual

Diagnostic and system error messages version 3.1.x reference guide
Hide thumbs Also See for StorageWorks 16-EL - SAN Switch:
Table of Contents

Advertisement

System Error Messages
Recommended Action
Check memory usage on the switch. Collect <function name> information
provided in the message and call Technical Support.
Severity
Error

RCS-RCSDISABLED

Message
<switch number> Debug RCS-RCSDISABLED, 5, RCS has been disabled. Some
switches in the fabric do not support this feature
Explanation
The RCS feature has been disabled on the local switch because not all switches in
the fabric support RCS. Currently, versions 2.6, 3.1, and 4.1 support the RCS
feature.
Recommended Action
Upgrade firmware to support RCS.
Severity
Debug
80
Diagnostic and System Error Messages Version 3.1.x Reference Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents