System Error Messages

NBFSM-NGBRSTATE

Message
<switch number> Error NBFSM-NGBRSTATE, 2, Wrong input: <state name> to
neighbor FSM, state <current state name>, port <port number>
Explanation
The wrong input was sent to the neighbor Finite State Machine.
Recommended Action
The input will be discarded. No user action is required.
Severity
Error

NBFSM-XMITFLAG

Message
<switch number> Warning NBFSM-XMITFLAG, 3, DB_XMIT_SET flag not set in
state <current state name> input <state name>, port <port number>
Explanation
From the current state, the database transmit set flag was not set for the specified
input state on the specified port.
Recommended Action
No user action required.
Severity
Warning