System Error Messages
Recommended Action
The SCN will be ignored. No user action is required.
Severity
Warning

FSPF-SECTION

Message
<switch number> Error FSPF-SECTION, 2, Wrong Section Id <section number>,
should be 0, input port = <port number>
Explanation
An incorrect section ID was reported from the specified input port. HP supports
only Section ID 0 (zero).
Recommended Action
Verify that the reported Section ID is 0 (zero).
Severity
Error

FSPF-VERSION

Message
<switch number> Error FSPF-VERSION, 2, FSPF Version <FSFP version> not
supported, input port = <port number>
Explanation
The specified FSPF version is not supported on the specified input port.