System Error Messages
Explanation
The primary Fibre Channel Switch (FCS) received a data request from the
specified domain. For example, if the switch fails to update the database or is
attacked (data injection), a message is generated to the primary FCS to try to
correct and re-synchronize with the rest of the switches in the fabric.
Recommended Action
Check the fabric status using secfabricshow to verify that the fabric is not
being attacked by unauthorized users.
Severity
Informational

SEC-SEC_STATS

Message
<switch number> Warning SEC-SEC_STATS, 3, Security statistics error: %s
Explanation
The switch logs each error for any statistic-related security command
(secstatsshow, secstatsreset) to keep track of any security violations
on the switch. The counter is updated automatically when a security violation
occurs. This message may also occur if the updating counter fails.
Recommended Action
If the message is the result of a user command, retry the statistic command. If the
problem persists, contact Technical Support.
Severity
Warning
88
Diagnostic and System Error Messages Version 3.1.x Reference Guide