System Error Messages

MS-OUT_RESOURCES

Message
<switch number> Error MS-OUT_RESOURCES, 2, MS Failure while initializing
<action>
Explanation
The Management Server (MS) failed while initializing the specified <action>.
The following can be displayed as <action>:
Recommended Action
The switch may be temporarily busy and out of resources to respond to a request.
If the error occurs frequently, check the available memory on the switch using
memshow and then contact Technical Support.
Severity
Error
MS-PLDBSEG
Message
<switch number> Warning MS-PLDBSEG, 3, MS Platform Segmented port =
<port number> (<reason for segmentation> D = <domain>)
Explanation
The Management Server (MS) has segmented from another switch <domain> at
the specified port <port number> due to errors or inconsistencies defined in the
MS Platform Service.
66
<while writing to ms_els_q>
Explanation: Unable to write a message to the MS Extended Link Service
Queue.
<while inserting timer to timer list>
Explanation: Unable to add timer to resource.