System Error Messages
Severity
Debug

MS-TIME_OUT

Message
<switch number> Error MS-TIME_OUT, 2, MS time out while <error>
Explanation
The Management Server (MS) timed out while acquiring a resource.
The following is displayed as the <error>:
Recommended Action
Reboot the switch and retry the request. If error recurs, contact Technical Support.
Severity
Error

MS-UNEXPECTED_IUDATASZ

Message
<switch number> Error MS-UNEXPECTED_IUDATASZ, 2, MS Unexpected iu_data_sz=
<number of bytes>
Explanation
The Management Server (MS) received Information Unit (IU) data of unexpected
size. The IU payload and the IU size may be inconsistent with each other or with
the command that is currently being processed.
Recommended Action
Retry the operation. If the error recurs, contact Technical Support.
70
<acquiring elsSemaRNID lock>
Explanation: Unable to acquire a semaphore lock for RNID.
Diagnostic and System Error Messages Version 3.1.x Reference Guide