Download Print this page

HP StorageWorks 16-EL - SAN Switch Reference Manual: Slap_secpolicyinit; Slap_signcheckfail

Diagnostic and system error messages version 3.1.x reference guide.
Hide thumbs

Advertisement

Recommended Action
Memory could be very low on the system. Reboot the switch and see if the
problem persists. If it persists after rebooting the switch, then the zoning
definitions or the like must be reduced to free-up memory.
Severity
Warning

SLAP_SECPOLICYINIT

Message
<switch number> Error SLAP-SECPOLICYINIT, 3, Security Policy Initialization
Failed
Probable Cause
The SLAP daemon failed to initialize the security library.
Recommended Action
The SLAP daemon did not start because the library initialization failed. Reboot
the switch and see if the problem persists. If the problem persists after reboot, call
HP Technical Support.
Severity
Warning
SLAP_SIGNCHECKFAIL
Message
<switch number> Error SLAP-SIGNCHECKFAIL, 3, Security Violation: Signature
verification failed on port %d
Probable Cause
The signature of a received challenge could not be verified.
Diagnostic and System Error Messages Version 3.1.x Reference Guide
SLAP_System Error Messages
101