Image Status Read Command; Cr_Bright Command; Cr_Cont Command; Cr_Color Command - Sanyo PLC-ZM5000L - 5000 Lumens Manual

Expand serial command function spcifications
Hide thumbs Also See for PLC-ZM5000L - 5000 Lumens:
Table of Contents

Advertisement

PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications

9.4 Image Status Read Command

9.4.1

CR_BRIGHT Command

Command
"CR_BRIGHT" [CR]
Details
Get user controlled value of Brightness
Acceptable
Response
%1
Unacceptable
9.4.2

CR_CONT Command

Command
"CR_CONT" [CR]
Details
Get user controlled value of Contrast
Acceptable
Response
%1
Unacceptable
9.4.3

CR_COLOR Command

Command
"CR_COLOR" [CR]
Details
Get user controlled value of Color
Acceptable
Response
%1
Unacceptable
9.4.4

CR_TINT Command

Command
"CR_TINT" [CR]
Details
Get user controlled value of Tint
Acceptable
%1
Response
Unacceptable
9.4.5

CR_IRIS Command

Command
"CR_IRIS" [CR]
Details
Get Iris function setting status
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"000 – 063"
"Error Code" [CR]
"000_%1" [CR]
"000 – 063"
"Error Code" [CR]
"000_%1" [CR]
"000 – 063"
"Error Code" [CR]
"000_%1" [CR]
"000 – 063"
"Error Code" [CR] --- When command is not available in the given
condition (such as being selected input).
"?" [CR] --- When unknown command is received
"000_%1" [CR]
"ON" ------------------------------ Set Iris function On
"OFF" ------------------------------ Set Iris function Off
"Error Code" [CR]
56/89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-zm5000Plc-zm5000l

Table of Contents