Overview; Serial Interface Specification; Transfer Specification; Connection - Sanyo PLC-ZM5000L - 5000 Lumens Manual

Expand serial command function spcifications
Hide thumbs Also See for PLC-ZM5000L - 5000 Lumens:
Table of Contents

Advertisement

PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
1

Overview

This Functional Specification defines communication with PJ-Net organizer for PLC-ZM5000 /
ZM5000L.
Supporting Firmware Ver. 1.x of the projector.
Commands in this document are to communicate with PJ-Net organizer, but most commands are
used to control a projector remotely from a computer with RS-232C. Therefore commands in this
document are defined as Expand Serial Commands.
2

Serial Interface Specification

2.1

Transfer Specification

Item
Synchronous System
Transmission Speed
Data Length
Parity
Stop Bit
Flow Control
Note1) Transmission Speed: initial setting value is 19200
Note2) Transmission Speed can be changed in Service mode.
2.2

Connection

Dedicated serial cables must be used for the connection between a computer and a projector.
Connect COM port of the computer to CONTROL PORT of the projector.
COM Port (COM1 or COM2) of a computer is specified by control software of the computer.
Asynchronous
9600 / 19200
8 bits
N/A
1
N/A
PC
COM 1
(D-Sub 9Pin)
9/89
Specification
Projector
CONTROL PORT
(D-Sub 9Pin)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-zm5000Plc-zm5000l

Table of Contents