PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
8.10.24
CF_FANSPEED Command
Command
"CF_FANSPEED_%1" [CR]
"MAX" ------------------------------ Select maximum fan speed
%1
"NOR" ------------------------------ Select normal fan speed
Switch Fan Control Speed mode.(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.10.25
CF_SIMPLEMODE Command
Command
"CF_SIMPLEMODE_%1" [CR]
"ON" ------------------------------ Set Simple mode to ON
%1
"OFF" ------------------------------ Set Simple mode to OFF
Set Simple mode.(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.10.26
CF_RCODE Command
Command
"CF_RCODE_%1" [CR]
"001" ------------------------------------ Select Code 1
"002" ------------------------------------ Select Code 2
"003" ------------------------------------ Select Code 3
"004" ------------------------------------ Select Code 4
"005" ------------------------------------ Select Code 5
%1
"006" ------------------------------------ Select Code 6
"007" ------------------------------------ Select Code 7
"008" ------------------------------------ Select Code 8
"UP" ---------- The same operation as pressing Up key or Left key
"DN" ----------The same operation as pressing Down key or Right key
Select Code of Remote Control (Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
47/89