PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
8.10.38
CF_SHUTPROT Command
Command
"CF_SHUTPROT_%1" [CR]
"OFF" ----------- RC and Side panel are both enabled.
"RC" ------------- RC is disabled.
%1
"KEY" ----------- Side panel is disabled.
"BOTH" --------- RC and Side panel are both disabled.
Set valid / invalid of Side panel or RC key on Shutter control function
Details
(Valid only when in the normal Power ON status)
Acceptable
Response
Unacceptable
8.10.39 CF_SHUTRELEASE Command
Command
"CF_SHUTRELEASE_%1" [CR]
"ANY"--------------------Enable to release Shutter with any key
%1
"SHUTTER" ---------- Enable to release Shutter with only "SHUTTER" key
Set Release key of Shutter.
(Valid only when in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.10.40
CF_SHUTH Command
Command
"CF_SHUTH_%1" [CR]
"005"-"480"----------Specify setting time directly
%1
"UP" ------------------ Add 1 minute
"DN" ------------------Decrease 1 minute
Set time of operating shutter management function.
(Valid only when in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains effective
even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.10.41
CF_CCAPTIONDISP Command
Command
"CF_CCAPTIONDISP_%1"[CR]
"OFF" ------------- Select Off
"CC1" ------------- Select CC1
%1
"CC2" ------------- Select CC2
"CC3" ------------- Select CC3
"CC4" ------------- Select CC4
Select channel of Closed caption.(Valid only when in the normal Power ON status)
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
Details
Note)Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video) and System is fixed
to NTSC.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000"[CR]
"Error Code"[CR]
51/89