1.
SMPALLOC
Allocate the SMP/E control dataset as necessary. If an existing SMP/E control dataset is to
be used, skip this step.
For examples of modifying sample JCL (SMPALLOC), see
Datasets)" (page
2.
HPQYK1AL
Allocate the distribution library (DLIB) and the target library.
For examples of modifying sample JCL (HPQYK1AL), see
and Target Libraries)" (page
3.
HPQYK2DF
Execute SMP/E DDDEF to define the distribution library (DLIB) and target library.
For examples of modifying sample JCL (HPQYK2DF), see
and Target Libraries)" (page
4.
HPQYK3RC
Execute SMP/E RECEIVE to load the provided datasets and store them in the global zone.
For examples of modifying sample JCL (HPQYK3RC), see
Processing)" (page
5.
HPQYK4AP
Execute SMP/E APPLY to install the provided dataset in the target library (the library shown
in
"DASD Storage Attributes for Target Libraries" (page
The APPLY command in the sample JCL specifies the CHECK operand. If execution with the
CHECK operand does not generate an error, delete the CHECK operand and re-execute the
job.
For examples of modifying sample JCL (HPQYK4AP), see
Libraries)" (page
6.
HPQYK5AC
Execute SMP/E ACCEPT to install the provided dataset in the distribution library (the library
shown in
command in the sample JCL specifies the CHECK operand. If execution with the CHECK operand
does not generate an error, delete the CHECK operand and re-execute the job.
For examples of modifying sample JCL (HPQYK5AC), see
Libraries)" (page
NOTE:
Execute the HPQYK5AC job carefully, and only after verifying that the installed product
works as designed when the HPQYK4AP job has been executed.

Simple Installation (Without SMP/E) Installation

This section explains installation that does not use SMP/E.
This method does not use SMP/E, instead, installation is performed directly from the provided
dataset to the target library.
Members of the sample JCL library being installed must be changed according to the user's
installation environment. Details are shown at the beginning of each sample JCL. For modification
examples, see
94).
96).
98).
101).
103).
"DASD Storage Attributes for Distribution Libraries (DLIB)" (page
104).
"Modifying Sample JCL" (page
"SMPALLOC (Allocating SMP/E
"HPQYK1AL (Allocating Distribution
"HPQYK2DF (Defining Distribution
"HPQYK3RC (SMP/E RECEIVE
17)).
"HPQYK4AP (Creating Target
"HPQYK5AC (Creating Distribution
88).
Installing Business Continuity Manager
17)). The ACCEPT
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents