Specifying The Host Id - HP StorageWorks P9000 Software Installation Manual

Business continuity manager software installation guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

For details about the YKDSPENV command format, see
For details about the YKSETENV command format, see
Table 18 (page 36)
set, their meanings, their corresponding system symbol names, and their default values.
Table 18 Business Continuity Manager Environment Variables That Can Be Set
Business Continuity
Manager environment
variable
YKCMDIF
YKLCNSE
YKLCNS2
LOGPUT
SYSLOG
1
For details about the relationship between the prefix of the license information dataset and the specification status for
the YKSETENV command or IEASYMxx parmlib member, see
(page
44).
2
For details about the system logger service, see the HP StorageWorks P9000 for Business Continuity Manager Software
User Guide.
Alternatively, you can define the corresponding system symbols in the IEASYMxx parmlib member
and then perform a re-IPL of the system to set values for the Business Continuity Manager environment
variables. If you cannot perform the re-IPL because the system is running, use the YKSETENV
command to set environment variables.
The priority order for specifying values is as follows:
1.
value-specified-by-the-YKSETENV-command
2.
value-specified-for-the-IEASYMxx-parmlib-member
3.
default-value
If the YKSETENV command is executed without specifying parameters, the corresponding system
symbol values are used as the Business Continuity Manager environment variables. If no value is
specified for the YKSETENV command parameters and the corresponding system symbols, the
default values are used as the Business Continuity Manager environment variables.
The following sections provide examples of configuring the environment. For details about how to
specify the prefixes for license information datasets, see
Information Datasets" (page
NOTE:
If you use the YKSETENV command to set Business Continuity Manager environment
variables, perform the procedure described in
Environments" (page

Specifying the Host ID

When the remote DKC control function is being used, to make multiple hosts (OSs) on the same
site use Business Continuity Manager and share one command device in a storage system, specify
the host IDs. If there is only one host (OS) on the site, or you do not make multiple hosts share one
command device, you do not need to specify the host ID.
For the host ID, specify a hexadecimal two-digit number from 00 to 1F that is unique for each OS.
In an LPAR environment, specify a different number for each LPAR.
36
Installing Business Continuity Manager
describes the Business Continuity Manager environment variables that can be
Meaning
Host ID
Prefix of the license
information dataset
Whether the system
2
logger service is used
Whether CLI
command-execution logs
are output to SYSLOG
44).
25).
"YKDSPENV Command Syntax" (page
"YKSETENV Command Syntax" (page
Corresponding system
Default value
symbol names
&YKCMDIF
00
&YKLCNSE and
HP
&YKLCNS2
LOGR: Uses the system
&YKLOGPT
logger service
YES: Outputs CLI
&YKSYSLG
command-execution logs
to SYSLOG
"Naming Conventions for License Information Datasets"
"Naming Conventions for License
"Settings for Using CLI Commands in TSO/E
1
30).
28).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500

Table of Contents