Security Settings (Option 6)

You can change security settings by means of Telnet or serial connections only, not on
the Web-Manager. We recommend that you set security over the dedicated network or
over the serial setup to prevent eavesdropping.
Caution:
accessing the setup menu from the network. Disabling Port 77FE also
disables the Web from configuring the device.
Select 6 to configure security settings.
Disable SNMP <N> ?
SNMP Community Name <public>:
Disable Telnet Setup <N> ?
Disable TFTP Firmware Update <N> ?
Disable Port 77FEh <N>
Disable Web Server <N> ?
Disable Web Setup <N> ?
Disable ECHO ports <Y> ?
Enable Enhanced Password <N> ?

Disable SNMP

This setting allows you to disable the SNMP protocol on the unit for security reasons. The
default setting is N (No).
Disable SNMP (N) ? _

SNMP Community Name

The SNMP Community Name is a required field for NMS to read or write to a device.
Enter a string of 1 to 13 characters. The default setting is public.
SNMP Community Name (public): _
The default entry is public. The current value is displayed in parentheses.

Disable Telnet Setup

Note:
If you choose to disable this option, keep in mind that disabling both Telnet
Setup and Port 77FE will prevent users from accessing the setup menu from the
network.
UDS1100 User Guide
Disabling both Telnet Setup and Port 77FE will prevent users from

Figure 9-2. Security Settings