Security Settings (Option 6); Figure 9-2. Security Settings - Lantronix XPress DR+ User Manual

Industrial device server
Hide thumbs Also See for XPress DR+:
Table of Contents

Advertisement

HTTP Port Number
This option allows the configuration of the web server port number. The valid range is
1-65535. The default HTTP port number is 80.
HTTP Port Number: (80) ? _
MTU Size
The Maximum Transmission Unit (MTU) is the largest physical packet size a network can transmit
for TCP and UDP. Enter between 512 and 1400 bytes. The default setting is 1400 bytes.
MTU Size (512 -1400): (1400)? _
TCP Re-transmission Timeout
This feature allows the configuration of the desired TCP re-transmission timeout value. If the ACK
is not received for a packet sent from the XPress Direct+ device, then the unit will retransmit the
data. The valid range is 500-4000 msec with 500 msec as default.
TCP Re-transmission Timeout (500 - 4000) (ms):
Enable alternate MAC
If necessary, enable the alternate MAC address (if specified in the OEM setup record). The
default setting is N (No).
Enable alternate MAC (N)? _

Security Settings (Option 6)

You can change security settings by means of Telnet or serial connections only, not on the Web
Manager. We recommend that you set security over the dedicated network or over the serial
setup to prevent eavesdropping.
Caution:
Disabling both Telnet Setup and Port 77FE will prevent users from
accessing Setup Mode from the network. Disabling Port 77FE also disables the
Web Manager and DeviceInstaller from configuring the device.
Select 6 to configure security settings.
Disable SNMP (N)?
SNMP Community Name (public):
Disable Telnet Setup (N)?
Disable TFTP Firmware Update (N)?
XPress™ DR+ Industrial Device Server User Guide

Figure 9-2. Security Settings

9: Setup Mode: Advanced Settings
(500)?
69