Assigning the IP Address: Serial Port Login

To assign the IP address and other network settings using a serial connection:
1. Connect a console terminal or a PC running a terminal emulation program to the
unit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity, 1
stop bit, no flow control.
2. To enter Setup Mode, cycle the unit's power (power off and back on). After power-up,
the self-test begins and the red Diagnostic LED starts blinking. You have one
second to enter three lowercase x characters.
Note:
terminal (or emulation) while powering up the unit.
3. Select 0 (Server Configuration) and follow the prompts until you get to
IP address.
4. Enter the new IP address, subnet mask, and gateway (if applicable).
5. Do one of the following:
UDS1100 User Guide
The easiest way to enter Setup Mode is to hold down the x key at the
Continue with
5: Configuration via Telnet or Serial Port (Setup Mode).
Select 9 to save and exit Setup Mode. The unit performs a power reset.
4: Using DeviceInstaller