10. Insert the end of the Color Reflection Reference strip with the arrow into the
calibration strip entrance on the DTP41, centering it below the alignment mark
(see the diagram on
Insert the strip about 3 inches, past the front idler rollers, until it rests against the rear
drive rollers.
11. Click Read Reference in the Instrument Calibration dialog box.
The DTP41 pulls the calibration strip through automatically.
A message appears in the Status area when the calibration is finished.
12. Click Done.
13. Close the Utilities window.
This completes DTP41 calibration.
When the DTP41 requires calibration, your computer prompts you. When the
prompt message appears, click Calibrate Now and follow the instructions, starting
with
step 8
on
After calibrating the DTP41, calibrate the Fiery X3e (see

Using the X-Rite DTP32 densitometer

ColorWise Pro Tools are designed to work with the X-Rite DTP32 reflection
densitometer, which feeds color measurements to the Fiery X3e automatically.
Measurements from other densitometers can be input using a simple
N
:
OTE
ASCII file format (see

Setting up the DTP32

Before you calibrate the Fiery X3e using the X-Rite DTP32, you need to connect,
configure, and calibrate the densitometer to prepare for measuring the printed patches
(see
"Calibrating the DTP32"
up and using the DTP32, see the separate documentation included with the
densitometer.
page
A-2).
page
A-7.
Appendix
B).
on page A-11). For additional information about setting