2-14 Color Calibration

Calibrating the Fiery X3e with the DTP32

Using the DTP32, you can quickly measure color patches and download these
measurements to the Fiery X3e using ColorWise Pro Tools Calibrator.
Before using ColorWise Pro Tools and the DTP32 to calibrate the Fiery X3e,
N
:
OTE
follow the instructions on
T
F
O CALIBRATE THE
IERY
1. Start Calibrator.
For instructions on starting Calibrator, see
2. In the Select Measurement Method pane, choose X-Rite DTP32.
3. In the Check Print Settings pane, choose the desired calibration set.
If more than one option appears, choose the appropriate calibration set for the type of
media you will use most often.
For this calibration to take effect, the calibration set must be associated with one
N
:
OTE
or more output profiles. The default calibration set is already associated with the
default output profile, so there is no need to make any new associations.
4. In the Generate Measurement Page pane, click Print.
The Print Options dialog box appears.
5. Choose the appropriate options, and click Print.
For Page Type, choose either 34 or 21 Sorted Patches.
Paper Size is automatically set to LTR/A4 for 21 Sorted Patches, or 11
34 Sorted Patches.
page A-11
for calibrating the DTP32 densitometer.
X3
DTP32
E USING THE
page
2-6.
17/A3 for
x