Infinity WF Operator Manual
2. As stated on the screen, place the control sheet – S008468 - (also known as the calibration
sheet) on the scan table and slide it into the scanner's transport. The scanner will align the
sheet by pulling it forward and back. Once it has finished, tap the >Cont. button
The Abort button immediately discontinues the procedure and returns you to the previous
screen
3. The control sheet will be pulled in and the measurement starts. While the measurement is
running a graphic symbol shows the progress
4. Once the procedure finishes and the control sheet is ejected from the transport, the Touch
Screen will display the results of the procedure
5. Click the Finish button when done
Lamp On / Off
Touch and hold the Lamp On / Off button to switch the lamps on. As long as the button is
touched, the lamps will illuminate. This feature is useful for cleaning and glass inspection.
Transport Control Arrows
The Transport Control Arrows (buttons) move the scanner's transport rollers for
cleaning and other adjustments as needed.
117
Page 28 of
Figure 4.5: White Balance screen
Figure 4.6: White Calibration Results screen