Brother BAS-364E Instruction Manual page 62

E series programmable electronic pattern sewer
Hide thumbs Also See for BAS-364E:
Table of Contents

Advertisement

I Memory Switches [40] - [4F] (Set using numbers instead of [on] or [oFF])
SW. No.
Setting range
memo-40
1 - 10
memo-41
1 - 10
memo-42
1 - 9
memo-43
1 - 9
memo-44
1 - 9
memo-45
-
memo-46
-
memo-47
-
memo-48
-
memo-49
-
memo-4A
-
memo-4b
-
memo-4c
-
memo-4d
-
memo-4E
-
memo-4F
-
,
/
*
1
5
-400 rpm , ± 0 rpm / + 400 rpm
I Memory Switches [50] - [5F] (Set using numbers instead of [on] or [oFF])
SW. No.
Setting range
memo-50
5 - 30
memo-51
5 - 30
memo-52
-
memo-53
-
memo-54
-
memo-55
-
memo-56
-
memo-57
-
memo-58
-
memo-59
-
memo-5A
-
memo-5b
-
memo-5c
-
memo-5d
-
memo-5E
-
memo-5F
-
Chapter 11 CHANGING SPECIAL FUNCTIONS AND USING THE MEMORY SWITCHES
Units
Default
✕ 7.5˚
5
✕ 7.5˚
5
-
5
-
5
-
5
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
9
Units
Default
%
15
%
15
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
BAS-364E, 366E, 370E, 375E
Changes the X feed timing
1 (Early) , 5 (Standard) / 10 (Late)
Changes the Y feed timing
1 (Early) , 5 (Standard) / 10 (Late)
Correct sewing speed: low speed data 667L*
Correct sewing speed: low speed data 668L*
Correct sewing speed: low speed data 669L*
-
-
-
-
-
-
-
-
-
-
-
Power supply voltage: up limit
Power supply voltage: down limit
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Description
Description